<< Chapter < Page Chapter >> Page >
Using the MSP-EXP430FG4618 Development Tool and the MSP430FG4618 device implement a Memory clock with Basic Timer1.

Laboratory timers: lab1 - memory clock with basic timer1

Introduction

Correct system timing is a fundamental requirement for the proper operation of a real-time application. The timing definition can dictate how the data information processed during the execution of the application program. The clock implementations vary between devices in the MSP430 family. Each device provides different clock sources, controls and uses. This chapter discusses the clock controls included in the platforms used. The MSP430 4xx family has two general-purpose 16-bit or 8-bit counters and event timers, named Timer_A, Timer_B, and a Basic Timer. The Basic Timer module is only implemented in ‘4xx devices. The 2xx device family also has Timer_A and Timer_B, but the clock signals are provided by the basic clock module+.The timers may receive an internal or external clock. Timer_A and Timer_B also include multiple independent capture and compare blocks, with interrupt capabilities.

Overview

This laboratory implements a memory clock using the features provided by Timer1. The clock is updated once every second by the Basic Timer1 interrupt service routine (ISR). This procedure also performs switching of LED1. In order to evaluate the execution time of the routine, LED2 is kept active during the execution of the ISR. When the ISR has completed, the device goes into low power mode, until the new interrupt wakes it up.

Resources

This application ( Lab1_Timers.c ) sets Basic Timer1 to generate an interrupt once every second. The interrupt service routine generated by this peripheral is required to update the clock stored in memory. Moreover, it must refresh the content of the clock displayed on the LCD.

Thus, the system resources used by this application are:

- Basic Timer1;

- I/O ports;

- LCD;

- Interrupts;

- Low power modes.

The default configuration of the FLL+ is used, so, all the clock signals required for the operation of the components of the device assume their default values.

Software application organization

The first task is to disable the Watchdog Timer. It should be stated that this feature, when used correctly, makes the application more robust.

The resources needed for the LCD are all configured. This code is given, since its operation will be analysed in a later laboratory. Once the LCD configured, it is cleared by the execution of the routine LCD_all_off() .

The memory clock consists of setting three global variables: hour, min, and sec, all of the type unsigned char, used to store the hours, minutes and seconds values elapsed respectively since the beginning of the execution of the application. These variables are initialized with zero values.

The LCD is refreshed at startup to show the initial clock value.

LED1 is used as an indicator of Basic Timer1 ISR execution. The execution time can be determined through it. In addition, LED2 state switches whenever the Basic Timer1 ISR is executed.

Questions & Answers

what is biology
Hajah Reply
the study of living organisms and their interactions with one another and their environments
AI-Robot
what is biology
Victoria Reply
HOW CAN MAN ORGAN FUNCTION
Alfred Reply
the diagram of the digestive system
Assiatu Reply
allimentary cannel
Ogenrwot
How does twins formed
William Reply
They formed in two ways first when one sperm and one egg are splited by mitosis or two sperm and two eggs join together
Oluwatobi
what is genetics
Josephine Reply
Genetics is the study of heredity
Misack
how does twins formed?
Misack
What is manual
Hassan Reply
discuss biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles
Joseph Reply
what is biology
Yousuf Reply
the study of living organisms and their interactions with one another and their environment.
Wine
discuss the biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles in an essay form
Joseph Reply
what is the blood cells
Shaker Reply
list any five characteristics of the blood cells
Shaker
lack electricity and its more savely than electronic microscope because its naturally by using of light
Abdullahi Reply
advantage of electronic microscope is easily and clearly while disadvantage is dangerous because its electronic. advantage of light microscope is savely and naturally by sun while disadvantage is not easily,means its not sharp and not clear
Abdullahi
cell theory state that every organisms composed of one or more cell,cell is the basic unit of life
Abdullahi
is like gone fail us
DENG
cells is the basic structure and functions of all living things
Ramadan
What is classification
ISCONT Reply
is organisms that are similar into groups called tara
Yamosa
in what situation (s) would be the use of a scanning electron microscope be ideal and why?
Kenna Reply
A scanning electron microscope (SEM) is ideal for situations requiring high-resolution imaging of surfaces. It is commonly used in materials science, biology, and geology to examine the topography and composition of samples at a nanoscale level. SEM is particularly useful for studying fine details,
Hilary
cell is the building block of life.
Condoleezza Reply
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Teaching and classroom laboratories based on the “ez430” and "experimenter's board" msp430 microcontroller platforms and code composer essentials. OpenStax CNX. May 19, 2009 Download for free at http://cnx.org/content/col10706/1.3
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Teaching and classroom laboratories based on the “ez430” and "experimenter's board" msp430 microcontroller platforms and code composer essentials' conversation and receive update notifications?

Ask