<< Chapter < Page Chapter >> Page >
This is a continuation of MOS Fabrication technology. It describes the process option of P implant below the field oxide to make component isolation doubly sure and the process option of buried layer and epitaxial layer to prevent Latch-Up.

SSPD_Chapter 6_Part 6_MOS ICs Fabrication Technology_to be continued2

Section 6.6.2.4 Process Options for Active Region and Well Formation.

There are many options for Well Formation but here we will consider only two options which are commonly used by the Industries. First option is “Field Implants under LOCOS region”. This option is a more reliable method of lateral isolation of the active MOS. Second option is “Buried and Epitaxial Layer”. The second option prevents Latching of MOS through parasitic BJT formation.

Option 1. “Field implants under LOCOS region”.

In the CMOS process flow till now, the implant energies of P and N tubs were carefully chosen to penetrate the thick field oxide. Implants would be masked only in fixed KPR covered area. When the implant penetrates the field oxide, it increases the substrate doping underneath the LOCOS region and prevents the formation of inversion layer under normal voltage condition. Thus field oxide isolation is achieved. But the stopping by thick oxide is statistical in nature. Hence the dose which needs to be implanted underneath the field oxide is not achieved while the well implant is taking place. To ensure an implant under the field oxide this implant has to be carried out in a separate step.

In Section 6.4.3 , Figure 6.7, the middle diagram contains the windows for local oxidation. The active regions are shielded by KPR/Si 3 N 4 /SiO 2 .Now Boron ions of implant dose of 1×10 13 cm -2 at 50keV is used for field implant. The implant energy will make the Boron ions pass through thin SiO 2 region but will be completely stopped by KPR/Si 3 N 4 /SiO 2 stack. The LOCOS region acquires a shallow P-type implant as shown in Figure 6.49.

After the P-type implant we remove the fixed KPR by oxygen plasma or by an organic solvent known as stripper. Next we do the Local Oxidation through the aperture in Si 3 N 4 . The structure obtained is shown in Figure 6.50.

By dry etching Si3N4 is removed. Now we follow the steps in Figure 6.46 and Figure 6.47. The final structure is shown in Figure 6.51.

Option 2. “Buried and Epitaxial layer” process option.

In CMOS formation there is always a problem of parasitic BJTs as shown in Figure 6.52

In the circuit given in Figure 6.52.A we find that body of (E)PMOS which is N-tub is connected to the source of PMOS which is P+.

Similarly body of (E)NMOS which is P-tub is connected to the source of NMOS which is N+.

Source to Bulk Voltage (Vsb) is kept zero in both cases so that Threshold voltage is maintained constant. If Vsb is not zero then Threshold Voltage will become a function of Vsb given by the following relation:

γ = body-effect parameter;________________________________________________

F = surface potential parameter;___________________________________________

Since both MOSs are Enhancement type hence both are Normally OFF type therefore their channels are shown broken.

Questions & Answers

what is biology
Hajah Reply
the study of living organisms and their interactions with one another and their environments
AI-Robot
what is biology
Victoria Reply
HOW CAN MAN ORGAN FUNCTION
Alfred Reply
the diagram of the digestive system
Assiatu Reply
allimentary cannel
Ogenrwot
How does twins formed
William Reply
They formed in two ways first when one sperm and one egg are splited by mitosis or two sperm and two eggs join together
Oluwatobi
what is genetics
Josephine Reply
Genetics is the study of heredity
Misack
how does twins formed?
Misack
What is manual
Hassan Reply
discuss biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles
Joseph Reply
what is biology
Yousuf Reply
the study of living organisms and their interactions with one another and their environment.
Wine
discuss the biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles in an essay form
Joseph Reply
what is the blood cells
Shaker Reply
list any five characteristics of the blood cells
Shaker
lack electricity and its more savely than electronic microscope because its naturally by using of light
Abdullahi Reply
advantage of electronic microscope is easily and clearly while disadvantage is dangerous because its electronic. advantage of light microscope is savely and naturally by sun while disadvantage is not easily,means its not sharp and not clear
Abdullahi
cell theory state that every organisms composed of one or more cell,cell is the basic unit of life
Abdullahi
is like gone fail us
DENG
cells is the basic structure and functions of all living things
Ramadan
What is classification
ISCONT Reply
is organisms that are similar into groups called tara
Yamosa
in what situation (s) would be the use of a scanning electron microscope be ideal and why?
Kenna Reply
A scanning electron microscope (SEM) is ideal for situations requiring high-resolution imaging of surfaces. It is commonly used in materials science, biology, and geology to examine the topography and composition of samples at a nanoscale level. SEM is particularly useful for studying fine details,
Hilary
cell is the building block of life.
Condoleezza Reply
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Solid state physics and devices-the harbinger of third wave of civilization. OpenStax CNX. Sep 15, 2014 Download for free at http://legacy.cnx.org/content/col11170/1.89
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Solid state physics and devices-the harbinger of third wave of civilization' conversation and receive update notifications?

Ask